Getinge's sterilizer load cars and transfer carriages
are the ideal accessories for your steam
sterilizers. They provide ease of movement
and are designed for ergonomic and
efficient loading and transfer of goods. All of
our loading equipment and accessories are
constructed of stainless steel for long life
under severe conditiions.
(1) 500 SERIES LOADING ACCESSORIES
500 SERIES “SMART ” FIXED HEIGHT TRANSFER TROLLEY AND LOAD CAR |
|
|
|
 |
|
Article No. |
|
Description |
|
Dimensions (L x W x H), in (mm) |
|
564710471 |
|
500 series “SMART” transfer trolley |
|
57.7 x 24.2 x 38.1 (1465.6 x 614.68 x 967.74) |
|
61301608380 |
|
500 series load car |
|
34.6 x 25.8 x 41.25 (878.8 x 655.3 x 1047.8) |
|
564710172 |
|
Trolley with dual-side handles |
|
36.8 x 18.3 x 17.6 (934.72 x 464.82 x 447.04) |
|
The Fixed Height Trolley is designed for ergonomic handling of loads between the
packing area and each sterilizer, or between the sterilizer and sterile storage. The
trolley is fabricated of tubular stainless steel with four twin-wheel swivel casters,
4.9 in (125 mm) in diameter. The two rear casters feature brake locks and the two
front casters feature directional (anti-swivel) locks. Press down to activate and
push up to release locks.
The Load Car has four durable brass casters. The frame is constructed of 304
stainless steel material. The two shelves are formed from 304 stainless steel
material and two stainless steel rods support each adjustable shelf.
|
(2) 600 SERIES LOADING ACCESSORIES
600 SERIES LOAD CAR |
|
|
|
 |
|
Article No. |
|
Description |
|
Dimensions (L x W x H), in (mm) |
|
61301607935 |
|
600 series – 39" (990.6 mm) load car kit with 3 wire rack shelves |
|
38.6 x 24.4 x 22.3 (980.44 x 619.76 x 556.42) |
|
564602270 |
|
600 series – 39" (990.6 mm) load car base with wire rack shelf |
|
|
|
61301607937 |
|
600 series – 51" (1295.4 mm) load car kit with 3 wire rack shelves |
|
50.4 x 24.4 x 22.3 (1280.2 x 619.76 x 556.42) |
|
564603470 |
|
600 series – 51" (1295.4 mm) load car base with wire rack shelf |
|
|
|
The 600 series load car is constructed with a stainless steel frame and includes a
bottom shelf platform for stability. Vertical corner members have intervals of holes
for inserting shelf support rods to adjust the shelf spacing. Additional rods can be
inserted to serve as load back-stops. Each basic load car includes one fixed shelf
and two adjustable shelves with support rods. The load car has a maximum load
capacity of 440 lbs (200 Kg) with each shelf having a capacity of 275 lbs (125 Kg).
The 440 lbs should be distributed evenly over the total number of shelves installed
on the load car.
|
600 SERIES “SMART ” LOAD TROLLEY |
|
|
|
 |
|
Article No. |
|
Description |
|
Dimensions (L x W x H), in (mm) |
|
564710672 |
|
600 series – 39" (990.6 mm) “SMART” load trolley, fixed height |
|
59 x 24.21 x 42 (1498.6 x 614.93 x 1066.8) |
|
564710674 |
|
600 series – 51" (1295.4 mm) “SMART” load trolley, fixed height |
|
70.43 x 24.21 x 42 (1788.9 x 614.93 x 1066.8) |
|
The “SMART” Load Trolley is used for ergonomic handling of loads between the
packing area and each sterilizer, or between the sterilizer and sterile storage. The
Trolley loading table is equipped with a manually operated load latch with two
positions. Turn the latch handle full to the left to dock with the sterilizer and allow
the Load Car to be inserted into the sterilizer chamber; or to unload the Load Car
from the chamber. Turn the handle full to the right to undock the trolley from the
sterilizer. This action also locks the Load Car in place on the trolley table.
|
(3) 700 SERIES LOADING ACCESSORIES
700 SERIES LOAD CAR AND TRANSFER CARRIAGE |
|
|
|
 |
|
Article No. |
|
Description |
|
Dimensions (L x W x H), in (mm) |
|
61301600644 |
|
700 series – 39" (990.6 mm) chamber load car |
|
36 x 24 x 32.5 (914.4 x 609.6 x 825.5) |
|
61301600645 |
|
700 series – 53" (1346.2 mm) chamber load car |
|
48 x 24 x 32.5 (1219.2 x 609.6 x 825.5) |
|
61301600646 |
|
700 series – 61" (1549.2 mm) chamber load car |
|
60 x 24 x 32.5 (1524 x 609.6 x 825.5) |
|
The 700 series load car frame is constructed of tubular stainless steel. The load car
is supplied with a fixed bottom shelf, for use as a flat bed, plus (2) adjustable SST
shelves. Each adjustable shelf has a pair of side rails and easily accommodates
various shapes and sizes and eight adjustable shelving elevations are provided to
meet various item heights. The side rails are full length and easily adjusted to hold
processed items within the frame of the load car.
|
700 SERIES LOAD CAR AND TRANSFER CARRIAGE (continued) |
|
|
|
|
|
Article No. |
|
Description |
|
Dimensions (L x W x H), in (mm) |
|
61301608855 |
|
700 series – 39" (990.6 mm) chamber transfer carriage |
|
24 x 20.9 (609.6 x 530.86) |
|
61301608856 |
|
700 series – 53" (1346.2 mm) chamber transfer carriage |
|
24 x 20.9 (609.6 x 530.86) |
|
61301608857 |
|
700 series – 61" (1549.4 mm) chamber transfer carriage |
|
24 x 20.9 (609.6 x 530.86 |
|
The transfer carriage is designed to be universal and compatible with previous
Castle sterilizers of similar size. The transfer carriage is fabricated of formed
stainless steel sections and rectangular stainless steel tubing, with high impact
phenolic threaded casters. The height is adjustable via the threaded casters. The
front casters are fixed, while the rear casters are swivel ball bearing, one with a
brake. Nylon bumpers extend from the latching mechanism for protection. A
self-centering latch provides alignment, and securely locks the carriage to the
sterilizer for an easy and safe transfer of the load. A locking mechanism holds the
load car securely on the transfer carriage. Two separate release mechanisms are
provided to: a) disengage the load car from the transfer carriage; and b) disengage
the transfer carriage from the sterilizer. Both release mechanisms can be either
hand or knee operated.
|
700 SERIES LOAD CAR AND TRANSFER CARRIAGE (continued) |
|
|
|
|
|
Article No. |
|
Description |
|
61301608861 |
|
3600 Transfer Carriage Upgrade Kit (all stainless steel construction) |
|
61301609059 |
|
3400 Transfer Carriage Upgrade Kit (painted grey enamel) |
|
For customers who have existing Transfer Carriages, two kits are available to
upgrade for interchangeability depending on manufacturing date.
|
(4) 800 SERIES LOADING ACCESSORIES
4003 floor LOADING CART |
|
|
|
 |
|
Article No. |
|
Description |
|
Dimensions (L x W x H), in (mm) |
|
61301605254 |
|
4003 loading cart (includes 2 shelves/rods and swivel casters) |
|
36.75 x 24.75 x 57.63 (933.45 x 628.65 x 1463.8) |
|
61301609557 |
|
4003RC loading cart (for use with Model 4004) (includes 2 shelves/rods and fixed casters) |
|
36.75 x 24.75 x 57.63 (933.45 x 628.65 x 1463.8) |
|
SK46523 |
|
4004 transfer carriage for 4003 loading cart |
|
|
|
The 4003 floor loading sterilizer cart is an all-purpose cart designed for processing,
transportation and storage. The cart is constructed to resist the corrosive action of
high temperature steam sterilization. The cart is specifically designed for use with
Getinge Floor Loading Sterilizers and Washers. Since the cart is mobile, it saves
space that would otherwise be dedicated for conventional transfer carriages.
|
(5) FDA 510(K) MAXIMUM WRAPPED INSTRUMENT TRAY LOADS
Chamber |
|
Dimensions (L x W x H), in (mm) |
|
Cu-Ft |
|
Liters |
|
510(K)# |
|
Model |
|
Trays |
|
Wt-lb |
|
Small |
|
17.5 x 17.5 x 26 (444.5 x444.5 x 660.4) |
|
4.6 |
|
130 |
|
K103504 |
|
400HC |
|
2 |
|
50 |
|
Small |
|
21 x 21 x 38 (533.4 x 533.4 x 965.2) |
|
9.7 |
|
275 |
|
K103504 |
|
500HC |
|
3 |
|
75 |
|
Mid-Medium |
|
26.5 x 26.5 x 26 (673.1 x 673.1 x 660.4) |
|
10.6 |
|
300 |
|
K070657 |
|
633HC |
|
4 |
|
64 |
|
Mid-Medium |
|
26.5 x 26.5 x 39 (673.1 x 673.1 x 990.6) |
|
15.5 |
|
450 |
|
K070657 |
|
633HC |
|
8 |
|
128 |
|
Mid-Medium |
|
26.5 x 26.5 x 51 (673.1 x 673.1 x 1295.4) |
|
20.7 |
|
586 |
|
K070657 |
|
633HC |
|
12 |
|
192 |
|
Medium |
|
26.5 x 36 x 39 (673.1 x 914.4 x 990.6) |
|
21.5 |
|
609 |
|
K120441 |
|
733HC-E |
|
10 |
|
250 |
|
Medium |
|
26.5 x 36 x 53 (673.1 x 914.4 x 1346.2) |
|
29.2 |
|
827 |
|
K120441 |
|
733HC-E |
|
15 |
|
375 |
|
Medium |
|
26.5 x 36 x 61 (673.1 x 914.4 x 1549.4) |
|
33.7 |
|
955 |
|
K120441 |
|
733HC-E |
|
20 |
|
500 |
|
Floor Loader |
|
26.5 x 62 x 42 (673.1 x 1574.8 x 1066.8) |
|
39.6 |
|
1121 |
|
K031259 |
|
833HC |
|
12 |
|
192 |
|
Floor Loader |
|
26.5 x 62 x 76 (673.1 x 1574.8 x 1930.4) |
|
72.3 |
|
2047 |
|
K031259 |
|
833HC |
|
24 |
|
384 |
|
PEEL POUCH STERILIZATION RACK |
|
|
|
 |
|
Article No. |
|
Description |
|
Dimensions (L x W x H), in (mm) |
|
61301609706 |
|
Peel Pouch Sterilization Rack |
|
6.5 x 6 x 6 (165.1 x 152.4 x 152.4) |
|
Designed to hold Plastic/Paper Peel Pouches in a vertical position during a
sterilization cycle - use inside a tray for ease and safety of load removal. This rack
provides spacing to insure sterilant contact to all surfaces and drainage if moisture
is present during a cycle.
|
INSTRUMENT BASKET |
|
|
|
 |
|
Article No. |
|
Description |
|
Dimensions (L x W x H), in (mm) |
|
9500006 |
|
Instrument Basket |
|
10.5 x 20.5 x 3.5 (266.7 x 520.7 x 88.9) |
|
Modular instrument tray with perforated bottom and solid sides to prevent small
instruments from sticking out. Includes carrying handle.
|
WATER SAVER PACKAGES |
|
|
|
 |
|
Article No. |
|
Description |
|
Dimensions (L x W x H), in (mm) |
|
61301609555 |
|
MP129E water saver upgrade package, 115 V for current model 800-Series steam sterilizers |
|
19 x 10 x 37 (482.6 x 254 x 939.8)
(w/o chiller coil), 19 x 10 x 63.4
(482.6 x 254 x 1610.4)
(w/ chiller coil) |
|
61301609267 |
|
MP129F water saver upgrade package,
115V for current model 400/500/600/700
steam sterilizers |
|
19 x 10 x 37 (482.6 x 254 x 939.8)
(w/o chiller coil), 19 x 10 x 63.4
(482.6 x 254 x 1610.4)
(w/ chiller coil) |
|
61301606548 |
|
Water saver coil for building-supplied
water chiller |
|
|
|
61301606605 |
|
Electric water chiller for all MP129 water
savers, 115V |
|
|
|
The Getinge MP-129 Water Saver Modernization Package is intended for use on
healthcare or scientific mechanical air-removal and gravity displacement Getinge
steam sterilizers. Water Consumption can be reduced significantly when the
equipment is operated as recommended in the sterilizer operating instruction.
|